Smell gas? Leave the property and call the National Gas Emergency Service on 0800 111 999, 24 hours.

Brand guide

Baxi boiler fault codes

Most Baxi boilers show an E followed by two or three digits, such as E119. Codes starting E1 are the common lockout and safety codes. The newer Baxi 200 and 400 combis use a different style with dots, such as E.02.07 or H.02.06, and both styles are listed here. Baxi Group also makes Potterton and Main boilers, which share the E codes.

Covers: Baxi 200, 400, 600 and 800 series, Duo-tec, Megaflo, Platinum and EcoBlue.

CodeWhat it meansCan you fix it?
E119 Low water pressureUsually DIY
E133 Gas supply interrupted or ignition failedCheck first
E118 Water pressure too lowUsually DIY
E110 Overheat safety thermostatCheck first
E125 Circulation faultCheck first
E160 Fan faultEngineer
E168 General lockoutCheck first
E28 Flue faultEngineer
E20 Heating temperature sensor faultEngineer
E09 Gas valve cable faultEngineer
E15 Gas valve command faultEngineer
E40 Return sensor faultEngineer
E50 Hot water sensor faultEngineer
E53 Flue obstructionEngineer
E55 Calibration neededEngineer
E78 Water pressure sensor faultCheck first
E83 Communication faultCheck first
E109 Pre-circulation faultCheck first
E128 Flame failureCheck first
E129 Flame loss during calibrationCheck first
E130 Flue thermostat trippedEngineer
E134 Gas valve open with no gasCheck first
E135 Gas supply interruptedCheck first
E154 Flow and return sensor test failedCheck first
E193 Pre-circulation faultCheck first
E270 Circulation faultCheck first
E321 Hot water sensor faultEngineer
E384 False flame signalEngineer
E.02.07 Low system pressureUsually DIY
H.02.06 Low pressure warningUsually DIY
E.04.10 Failure to lightCheck first
E.01.04 Flame lost five timesCheck first
H.03.02 No flame detectedCheck first
E.01.12 Reset requiredCheck first
E.01.17 No circulationCheck first
E.01.20 Flue gas too hotEngineer
E.02.00 Reset in progressNo fault
E.04.03 Critical flow temperatureCheck first
E.04.12 False flame signalEngineer
E.04.13 Fan blockedEngineer
H.01.00 Gas valve communication lostEngineer

Resetting a Baxi boiler

Press and hold the reset button for one to three seconds, or until the boiler restarts. On older dial models, turn the selector to reset and hold it for about five seconds.

Before you call anyone

Most Baxi faults we see searched for come down to three things: low water pressure, no gas reaching the boiler, or a frozen condensate pipe in winter. Check all three first.

Need an engineer?

For anything beyond the safe checks on this page, use a Gas Safe registered engineer. Find one near you, or check an engineer's ID, on the official Gas Safe Register (free helpline 0800 408 5500).