Smell gas? Leave the property and call the National Gas Emergency Service on 0800 111 999, 24 hours.

Brand guide

Worcester Bosch boiler fault codes

Worcester Bosch boilers usually show a two-character code such as EA, followed by a three-digit cause code such as 227. The cause code tells you more precisely what went wrong, so note both. The Greenstar 8000 Style uses four-digit codes such as 1017 and 2971 instead, and those are listed here too.

Covers: Greenstar i, Greenstar Si, Greenstar CDi, Greenstar 4000 and 8000.

CodeWhat it meansCan you fix it?
EA 227 No flame detected after ignitionCheck first
EA 229 Flame lost while runningCheck first
A21 Lost signal from wireless thermostatUsually DIY
E9 224 Overheat safety cut-outCheck first
C6 Fan faultEngineer
A1 281 Pump stuck or running dryUsually DIY
F7 Flame detected when offEngineer
A7 Hot water sensor faultEngineer
A8 Controls communication faultCheck first
B1 Code plug not detectedEngineer
B7 257 Internal control board errorEngineer
C1 264 Fan stopped during operationEngineer
C4 273 Fan or airflow check faultEngineer
C7 214 Fan not runningEngineer
CC Outdoor sensor faultCheck first
D1 240 Return sensor faultEngineer
D3 External temperature limiterCheck first
D4 271 Temperature rising too fastCheck first
D5 Condensate pump failureEngineer
E2 222 Flow sensor faultEngineer
E5 218 Flow temperature too highCheck first
E9 219 Heat exchanger overheatedCheck first
EA 234 Gas valve coil disconnectedEngineer
EA 261 Ignition timing errorCheck first
EA 338 Too many short burner startsUsually DIY
EF 349 Flow and return temperature gap too bigCheck first
F0 237 Internal errorEngineer
FA 306 Flame detected after shut-offEngineer
FA 364 Gas valve leak test failed (EV2)Engineer
FB 365 Gas valve leak test failed (EV1)Engineer
FD 231 Power interruptedUsually DIY
9A 362 Wrong control module fittedEngineer
9U 233 Control module or code plug faultEngineer
H11 Hot water sensor maintenance warningEngineer
H13 Service dueNo fault
1017 Water pressure too lowUsually DIY
2971 System pressure too lowUsually DIY
2970 Pressure dropping too fastEngineer
1065 Pressure sensor faultCheck first
2927 Flame failed during operationCheck first
2948 No flame signalCheck first
2964 Heat exchanger flow too lowCheck first
2965 Flow temperature too highCheck first
2966 Flow temperature rising too fastCheck first
1010 Controls bus cable faultCheck first
1021 Hot water sensor faultEngineer
1037 Outside sensor faultCheck first
1073 Flow sensor short circuitEngineer
2924 Gas valve feedback faultEngineer

Resetting a Worcester Bosch boiler

Press the reset button (marked with a circular arrow or the word reset) and hold it for a few seconds until the display changes.

Before you call anyone

Most Worcester Bosch faults we see searched for come down to three things: low water pressure, no gas reaching the boiler, or a frozen condensate pipe in winter. Check all three first.

Need an engineer?

For anything beyond the safe checks on this page, use a Gas Safe registered engineer. Find one near you, or check an engineer's ID, on the official Gas Safe Register (free helpline 0800 408 5500).